80 to 501 Nominal Tons 140 to 350 Nominal Tons with Greenspeed® Intelligence
AquaForce 30XA with Greenspeed® Intelligence chillers were designed from the ground up to meet the efficiency demands of today and the future by providing premium air-cooled chiller packages for contractors, consulting engineers and building owners. Value-added features include rotary screw compression, R-134a HFC refrigerant, a quiet AeroAcoustic™ fan system, easy to use ComfortLink™ controls, microchannel condenser coil technology, and an optional integrated hydronic pump package with or without VFD.
Air cooled chillers within the scope of the ACCL certification program are certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org
Performance Features
Full-load EER values up to 10.9 and IPLV values up to 15.5
ASHRAE 90.1 compliant / AHRI certified
Operation from -20 F to 125°F ambient conditions
High-efficiency screw compressors
Standard uncoated or optional e-coated Novation® microchannel heat exchanger (MCHX) condenser coils
Hydronic pump package, available with or without VFD on sizes 090-160
Touch Pilot™ display with color touch screen with trending capability and web-based connection
Single or dual-point electrical connections available (factory-installed option)
Control transformer (factory-installed option)
Structurally robust base
Circuit setter provided with optional pump package (factory-installed option)
Standard Warranty
3 year coil parts only on Novation microchannel heat exchanger
One year from start-up or 18 months from shipment limited warranty
Extended warranty packages available
ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 80-501)
Size
Capacity
Total Power (kW)
Full Load
IPLV
Cooler Flow Rate
Cooler Pressure Drop
Tons
kW
EER
COP
EER
COP
GPM
L/s
ft wg
kPa
80
75.6
265.9
91.6
9.9
2.9
14.2
4.2
181.3
11.4
11.7
34.9
90
84.8
298.2
95.1
10.7
3.1
14.6
4.3
203.4
12.8
11.4
34
100
93.9
330.2
107.8
10.5
3.1
15
4.4
225.4
14.2
13.7
40.9
110
102.4
360.1
118.6
10.4
3
15.2
4.4
245.8
15.5
13.9
41.5
120
110.7
389.3
129.5
10.3
3
15.2
4.4
265.7
16.8
11.9
35.5
140
132.8
467
148.7
10.7
3.1
14.4
4.2
318.8
20.1
13.3
39.7
160
152.3
535.6
173
10.6
3.1
14.8
4.3
365.5
23.1
13.1
39.1
180
171.3
602.4
192.1
10.7
3.1
14.3
4.2
411.1
25.9
15.5
46.2
200
194
682.3
217.2
10.7
3.1
14.8
4.3
465.6
29.4
13.2
39.4
220
211.7
744.5
239.6
10.6
3.1
14.5
4.2
508
32
15.5
46.2
240
228.1
802.2
264.1
10.4
3
14.8
4.3
547.5
34.5
17.8
53.1
260
250.9
882.4
281.7
10.7
3.1
14.3
4.2
602.2
38
10.3
30.7
280
268.5
944.3
301.2
10.7
3.1
14.3
4.2
644.3
40.6
11.6
34.6
300
287.5
1011.1
326.3
10.6
3.1
14.9
4.4
690
43.5
13.1
39.1
325
306.6
1078.3
347.1
10.6
3.1
14.3
4.2
735.9
46.4
13.5
40.3
350
324.1
1139.8
374.8
10.4
3
14.4
4.2
777.7
49.1
14.9
44.4
400
383.6
1349.1
449.4
10.2
3
14.8
4.3
920.7
58.1
10.4
31
401
396.3
1393.9
464
10.2
3
13.4
3.9
951.2
59.8
20.8
61.6
450
426.7
1500.6
509.2
10.1
2.9
14.1
4.1
1024.1
64.6
10.1
30.1
451
435.6
1532.2
503.9
10.4
3
13.6
4
1045.5
65.7
25.3
75.1
476
459.2
1615
554.3
9.9
2.9
14
4.1
1102
69.3
22.6
67.1
500
458
1610.7
549.1
10
2.9
14.3
4.2
1099.2
69.3
12.1
36.1
501
494.1
1737.8
580
10.2
3
13.8
4.1
1185.8
74.6
26.1
77.6
ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 80-501)
Size
Capacity
Total Power (kW)
Full Load
IPLV
Cooler Flow Rate
Cooler Pressure Drop
Tons
kW
EER
COP
EER
COP
GPM
L/s
ft wg
kPa
80
75.8
266.6
90.1
10.1
3
14.5
4.2
182
11.5
11.8
35.2
90
85.2
299.6
93.4
10.9
3.2
14.8
4.3
204.5
12.9
11.5
34.3
100
94.4
332
105.7
10.7
3.1
15.3
4.5
226.7
14.3
13.9
41.5
110
103
362.2
116.4
10.6
3.1
15.4
4.5
247.2
15.6
14.1
42.1
120
111.4
391.8
127.2
10.5
3.1
15.5
4.5
267.4
16.9
12
35.8
140
133.4
469.1
146.4
10.9
3.2
14.7
4.3
320.1
20.2
13.4
40
160
153.1
538.4
170.1
10.8
3.2
15
4.4
367.3
23.2
13.2
39.4
180
172
604.9
189.2
10.9
3.2
14.5
4.2
412.8
26
15.6
46.5
200
194.9
685.4
213.7
10.9
3.2
15.1
4.4
467.8
29.5
13.3
39.7
220
212.7
748
235.7
10.8
3.2
14.7
4.3
510.4
32.2
15.7
46.8
240
229.2
806.1
260.1
10.6
3.1
15
4.4
550.1
34.7
18
53.7
260
251.7
885.2
278.8
10.8
3.2
14.4
4.2
604
38.1
10.3
30.7
280
269.3
947.1
298
10.8
3.2
14.5
4.2
646.3
40.8
11.6
34.6
300
288.3
1013.9
323.3
10.7
3.1
15
4.4
691.8
43.6
13.2
39.4
325
307.1
1080
344.8
10.7
3.1
14.4
4.2
737.1
46.5
13.6
40.6
350
324.5
1141.2
372.7
10.5
3.1
14.5
4.3
778.8
49.1
15
44.7
400
385
1354
444.1
10.4
3
14.9
4.4
924
58.3
10.5
31.3
401
396.8
1395.7
462
10.3
3
13.5
4
952.4
59.9
20.8
61.8
450
427.6
1503.8
505.5
10.2
3
14.2
4.2
1026.3
64.7
10.1
30.1
451
436.2
1534.1
501.7
10.4
3.1
13.8
4
1046.8
65.8
25.4
75.3
476
459.8
1617
552
10
2.9
14.1
4.1
1103.4
69.4
22.7
67.2
500
459.1
1614.6
544.8
10.1
3
14.4
4.2
1101.8
69.5
12.2
36.4
501
494.7
1740
577.3
10.3
3
14
4.1
1187.4
74.7
26.2
77.8
Legend:
AL - Aluminum COP - Coefficient of Performance CU - Copper EER - Energy Efficiency Ratio IPLV - Integrated Part Load Value MCHX - Microchannel Heat Exchanger
Notes:
Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
Standard rating conditions are as follows: Cooler Conditions: Leaving water temperature: 44 F (6.7 C) Flow rate: 2.4 gpm/ton (0.043 l/s per kW) Fouling Factor: 0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W) Condenser Conditions: Entering air temperature: 95 F (35 C)
Units configured with no suction service valve or suction line insultation.
Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.
Weights & Dimensions (Sizes 80-501)
Size
Operating Weight (lb)
Dimensions (ft-in)
AL/CU Coil
CU/CU Coil
MCHX Coil
Length
Width
Height
80
7674
8398
7234
11-10
7-4 3/4
7-6 7/16
82
7831
8555
7391
11-10
7-4 3/4
7-6 7/16
90
9959
10924
9382
15-9
7-4 3/4
7-6 7/16
92
10083
11048
9506
15-9
7-4 3/4
7-6 7/16
100
10186
11151
9603
15-9
7-4 3/4
7-6 7/16
102
10310
11275
9727
15-9
7-4 3/4
7-6 7/16
110
10326
11291
9738
15-9
7-4 3/4
7-6 7/16
112
10563
11528
9975
15-9
7-4 3/4
7-6 7/16
120
10471
11436
9877
15-9
7-4 3/4
7-6 7/16
122
10681
11646
10087
15-9
7-4 3/4
7-6 7/16
140
12760
13966
12023
19-8
7-4 3/4
7-6 7/16
142
13217
14423
12480
19-8
7-4 3/4
7-6 7/16
160
13003
14209
12255
19-8
7-4 3/4
7-6 7/16
162
13429
14635
12681
19-8
7-4 3/4
7-6 7/16
180
13590
15037
12699
23-7
7-4 3/4
7-6 7/16
182
13935
15382
13044
23-7
7-4 3/4
7-6 7/16
200
13712
15159
12810
23-7
7-4 3/4
7-6 7/16
202
14014
15461
13112
23-7
7-4 3/4
7-6 7/16
220
14727
16295
13748
27-6
7-4 3/4
7-6 7/16
222
15071
16639
14092
27-6
7-4 3/4
7-6 7/16
240
14887
16455
13897
27-6
7-4 3/4
7-6 7/16
242
15231
16799
14241
27-6
7-4 3/4
7-6 7/16
260
16853
18662
15720
31-5
7-4 3/4
7-6 7/16
262
17055
18864
15922
31-5
7-4 3/4
7-6 7/16
280
17022
18831
15878
31-5
7-4 3/4
7-6 7/16
282
17224
19033
16080
31-5
7-4 3/4
7-6 7/16
300
17362
19292
16141
31-5
7-4 3/4
7-6 7/16
302
17834
19764
16613
31-5
7-4 3/4
7-6 7/16
325
18834
21005
17467
36-4
7-4 3/4
7-6 7/16
327
19306
21477
17939
36-4
7-4 3/4
7-6 7/16
350
19040
21211
17659
36-4
7-4 3/4
7-6 7/16
352
19512
21683
18131
36-4
7-4 3/4
7-6 7/16
400
24578
26990
23038
39-3
7-4 3/4
7-6 7/16
401
22690
25102
20782
39-3
7-4 3/4
7-6 7/16
450
26600
29254
24901
43-2
7-4 3/4
7-6 7/16
451
23421
26075
21324
43-2
7-4 3/4
7-6 7/16
476
27520
30174
25422
43-2
7-4 3/4
7-6 7/16
500
26894
29547
25167
43-2
7-4 3/4
7-6 7/16
501
29883
33019
27403
51-3
7-4 3/4
7-6 7/16
ARI Capacity Ratings for Units with AL/CU Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence
Size
Capacity
Total Power (kW)
Full Load
IPLV
Cooler Flow Rate
Cooler Pressure Drop
Tons
kW
EER
COP
EER
COP
GPM
L/s
ft wg
kPa
140
131.7
463.1
149.5
10.6
3.1
17.3
5.1
316
19.9
13.1
39.1
160
149.5
525.7
175.2
10.2
3
17.4
5.1
358.8
22.6
12.7
37.9
180
169.2
595.2
190
10.7
3.1
17.3
5.1
406.2
25.6
15.2
45.4
200
190.2
669
220.8
10.3
3
17.5
5.1
456.5
28.8
12.8
38.1
220
211.9
745.1
242.7
10.5
3.1
17.2
5.1
508.5
32.1
15.5
46.5
240
225.4
792.7
264
10.2
3
17.5
5.1
540.9
34.1
17.4
52.1
260
251.4
884.1
284.4
10.6
3.1
17.8
5.2
603.3
38.1
10.3
30.8
280
266
935.5
303.9
10.5
3.1
17.7
5.2
638.4
40.3
11.4
34
300
281.3
989.2
327.9
10.3
3
17.8
5.2
675
42.6
12.6
37.8
325
304.2
1069.8
347.5
10.5
3.1
17.8
5.2
730
46.1
13.3
39.8
350
320.7
1127.9
367.2
10.5
3.1
17.9
5.2
769.7
48.6
14.7
43.8
ARI Capacity Ratings for Units with MCHX Condenser Coils (Sizes 140-350) With GreenSpeed® Intelligence
Size
Capacity
Total Power (kW)
Full Load
IPLV
Cooler Flow Rate
Cooler Pressure Drop
Tons
kW
EER
COP
EER
COP
GPM
L/s
ft wg
kPa
140
132.6
466.4
147.2
10.8
3.2
17.5
5.1
318.3
20.1
13.2
39.6
160
150.6
529.5
172.7
10.5
3.1
17.7
5.2
361.4
22.8
12.8
38.4
180
170.4
599.3
187
10.9
3.2
17.5
5.1
409
25.8
15.4
46
200
191.5
673.6
217.9
10.5
3.1
17.8
5.2
459.7
29
12.9
38.6
220
213.5
750.8
238.8
10.7
3.1
17.5
5.1
512.4
32.3
15.8
47.1
240
227.1
798.7
259.7
10.5
3.1
17.8
5.2
545.1
34.4
17.7
52.8
260
252.6
888.4
281.5
10.8
3.2
17.9
5.2
606.2
38.2
10.4
31.1
280
267.3
940.3
300.5
10.7
3.1
17.8
5.2
641.6
40.5
11.5
34.3
300
282.6
993.8
324.8
10.4
3.1
18
5.3
678.2
42.8
12.7
38.1
325
305.1
1073.1
345
10.6
3.1
17.9
5.3
732.3
46.2
13.4
40
350
321.6
1130.9
365.1
10.6
3.1
18.1
5.3
771.8
48.7
14.7
44.1
Legend:
AL - Aluminum COP - Coefficient of Performance CU - Copper EER - Energy Efficiency Ratio IPLV - Integrated Part Load Value MCHX - Microchannel Heat Exchanger
Notes:
Rated in accordance with AHRI Standard 550/590 at standard rating conditions.
Standard rating conditions are as follows: Cooler Conditions: Leaving water temperature: 44 F (6.7 C) Flow rate: 2.4 gpm/ton (0.043 l/s per kW) Fouling Factor: 0.00010 hr x sq ft °F/Btu (0.000018 m2 x °C/W) Condenser Conditions: Entering air temperature: 95 F (35 C)
Units configured with no suction service valve or suction line insultation.
Unit performances will vary depending on the options configured. All data in the above tables was generated in Packaged Chiller Builder version 3.49a. Refer to the latest version of the Packaged Chiller Builder for the most up-to-date data.
Weights & Dimensions (Sizes 140-350) With GreenSpeed® Intelligence
Size
Operating Weight (lb)
Dimensions (ft-in)
AL/CU Coil
CU/CU Coil
MCHX Coil
Length
Width
Height
140
12,390
13,596
11,653
22-0
7-4 3/4
7-6 7/16
160
12,633
13,839
11,885
22-0
7-4 3/4
7-6 7/16
180
14,476
15,923
13,585
25-11
7-4 3/4
7-6 7/16
200
14,598
16,045
13,696
25-11
7-4 3/4
7-6 7/16
220
15,613
17,181
14,634
29-10
7-4 3/4
7-6 7/16
240
15,773
17,341
14,783
29-10
7-4 3/4
7-6 7/16
260
17,930
19,739
16,797
33-9
7-4 3/4
7-6 7/16
280
18,099
19,908
16,955
33-9
7-4 3/4
7-6 7/16
300
18,439
20,369
17,218
33-9
7-4 3/4
7-6 7/16
325
20,102
22,273
18,735
37-8
7-4 3/4
7-6 7/16
350
20,308
22,479
18,927
37-8
7-4 3/4
7-6 7/16
Factory-Installed Options
Service option
Condenser coil trim panels
Full end screen
Hydronic pump package with or without VFD (sizes 090-160)