Nu-Calgon Rx-Acid Scavenger® Canister (Pressurized) 3.8 oz.
APPLICATIONS
Acid neutralizer for air conditioning & refrigeration systems:
• For compressor burnout
• For system maintenance
One kit for all oils. Use with:
• Mineral oil
• Alkylbenzene oil
• POE oil
• PVE oil
FEATURES & BENEFITS
• Eliminates acid build-up in A/C and refrigeration systems
• Protects against future acid circulation
• Helps prevent compressor burnout
• Compatible with all oils and refrigerants (except ammonia)
• System safe - leaves no harmful by-products
• Rx-Acid Scavenger Connect Inject uses a quick one-time disposable injector
• Connect Inject version uses new formula to improve acid scavenging rate in POE lubricant systems
• The Rx-Acid Scavenger family of products provides a convenient way to neutralize or “scavenge” acid in refrigeration, air conditioning systems after burnouts or during normal on-going system maintenance. Normal dosage treatment of any Rx-Acid Scavenger product will address up to one gallon of system oil. All Rx-Acid Scavenger products are formulated for use with all lubricants - mineral, alkylbenzene, polyol ester (POE) and polyvinyl ether (PVE) lubricants. The traditional Rx-Acid Scavenger product uses a two fluid ounce treatment, whereas the new Rx-Acid Scavenger Connect Inject uses a new formulation to improve the acid scavenging rate in POE and PVE lubricant systems.
DIRECTIONS
• If system’s low side pressure is BELOW 65 PSI while running:
• Shake can well. Make sure system is running and low side is below 65 psi.
• Be sure Injection Valve handle (4300-89) is turned fully counter clockwise and attach valve to can.
• Attach short charging hose to Injection Valve and other end to low side service port. Loosen valve slightly from can to purge air from hose and then re-tighten quickly.
• With can upright, open valve by turning handle clockwise and hold above low side service port to dispense.
• Allow approximately 1 minute for Rx-Acid Scavenger to completely enter the system.
• Once product is dispensed, remove hose from system. Retain hose and valve for future installations and dispose of can properly.
• If system’s low side pressure is ABOVE 65 PSI while running:
• First pump the system down to achieve a low side pressure between 40 and 50 psi. Then, inject into the low side starting with step 2 above.
Specification | |
---|---|
Capacity | 3.8 oz. |
Safety Standards | |
---|---|
California Prop 65 | Yes |
Weights and Dimensions | |
---|---|
Operating Weight (lbs) | 0.5 | Exterior Dimensions (D) (inches) | 2.000000 | Exterior Dimensions (W) (inches) | 2.000000 | Exterior Dimensions (H) (inches) | 5.000000 | Shipping Weight (lbs) | 2.500000 |