48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat

  • California Prop 65
Grouped product items
Product Name
Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1
MFR:
Item:
48FCDA04A2A30A0A0
Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDA04A2A50A0A0
Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDA04A2A60A0A0
Carrier 4 Ton, 13.8 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1
MFR:
Item:
48FCDA05A2A30A0A0
Carrier 4 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDA05A2A50A0A0
Carrier 4 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDA05A2A60A0A0
Carrier 5 Ton, 13.6 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1
MFR:
Item:
48FCDA06A2A30A0A0
Carrier 5 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDA06A2A50A0A0
Carrier 5 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDA06A2A60A0A0
Carrier 6 Ton, 11.0 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDM07A2A50A0A0
Carrier 6 Ton, 11.0 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDM07A2A60A0A0
Carrier 7.5 Ton, 11.2 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDM08A2A50A0A0
Carrier 7.5 Ton, 11.2 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDM08A2A60A0A0
Carrier 8.5 Ton, 11.2 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDM09A2A50A0A0
Carrier 8.5 Ton, 11.2 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDM09A2A60A0A0
Carrier 10 Ton, 11.0 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,208/3
MFR:
Item:
48FCDM12A2A50A0A0
Carrier 10 Ton, 11.0 EER Package RTU Low Gas Heating/Electric Cooling, Two Stage Cooling, Direct Drive/EcoBlue ,460/3
MFR:
Item:
48FCDM12A2A60A0A0

WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology

OVERVIEW

Gas Heating / Electric Cooling

3 to 27.5 Nominal Tons

Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units* is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multiefficiency offering.

*Available on select models

FEATURES

Performance Features

  • Meets and exceeds ASHRAE 90.1 energy efficiency levels
  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07 models
  • SEERs up to 14.0, IEER of 15.0
  • Gas efficiencies up to 82%
  • Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation and burner control logic
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector

Standard Limited Warranty

  • 10 years parts only heat exchanger - aluminized
  • 15 years parts only heat exchanger - stainless steel
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available

California residents please see Proposition 65

OPTIONS

Factory-Installed Options

  • Temperature Sensing EconoMi$er with relief
  • Enthalpy Sensing EconoMi$er with relief
  • Humidi-MiZer® Adaptive Dehumidification System
  • Multiple Gas Heat Sizes
  • Stainless Steel Gas Heat Exchangers
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • SystemVu™ Integrated Communicating Controls
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available

PHYSICAL DATA

Gas Heating/Electric Cooling Models (48FC)

Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) LxWxH Low Gas Heating Input (Btuh) Medium Gas Heating Input (Btuh) High Gas Heating Input (Btuh) Approx. Unit Weight (lbs)
3 1 (14.0) 74 x 47 x 33 67 110 -- 482
4 1 (14.0) 74 x 47 x 33 67 110 150 543
5 1 (14.0) 74 x 47 x 33 67 110 150 556
6 2 15.0 74 x 47 x 41 67 110 150 607

AHRI = Air-Conditioning, Heating & Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
IEER = Integrated Energy Efficiency Ratio
SEER = Seasonal Energy Efficiency Ratio

NOTES
1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate.
2. Ratings are based on:
» Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp.
3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard.
4. 48FC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap-energy.org