50KC WeatherMaker® Single-Package Rooftop Standard Efficiency – 14 SEER Electric Cooling Units with Optional Electric Heat

  • California Prop 65
Grouped product items
Product Name
50KCA04A2A50A0A0 3t packaged rooftop heat pump
MFR:
Item:
50KCA04A2A50A0A0
50KCA04A2A60A0A0 5t packaged rooftop heat pump
MFR:
Item:
50KCA04A2A60A0A0
50KCA05A2A50A0A0 pkg rftop 4 ton - 208/230-3-60
MFR:
Item:
50KCA05A2A50A0A0
50KCA05A2A60A0A0 4t packaged rooftop unit 460v
MFR:
Item:
50KCA05A2A60A0A0
50KCA06A2A50A0A0 packaged rooftop heat pump 5t
MFR:
Item:
50KCA06A2A50A0A0
50KCA06A2A60A0A0
MFR:
Item:
50KCA06A2A60A0A0

Single-Package Rooftop
Standard Efficiency – 14 SEER
Electric Cooling Units with Optional Electric Heat

3 to 5 Nominal Tons

50KC WEATHERMAKER® rooftop unit were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in cooling mode.

Performance Features

  • ASHRAE 90.1 compliant
  • Single-stage cooling capacity control
  • Up to 14.1 SEER and 12.0 EER
  • Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • Control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • Direct Drive – ECM indoor fan motor standard with optional belt drive systems available
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as installed Carrier 3-5 ton rooftops back to 1989, reducing installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas, electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Liquid line filter drier as standard

Standard Limited Warranty

  • 5 years parts only electric heater
  • 5 years parts only compressor
  • One year parts only on all other parts
  • Additional extended warranty packages available
Nominal Cooling Ton SizeCooling StagesAHRI Efficiency (SEER) EERDimensions (in) LxWxHElectric Heat Nominal kW RangeApprox. Unit Weight (lbs)
31(14.0)74x47x334.0 to 20.0445
41(14.0)74x47x334.0 to 20.0499
51(14.1)74x47x415.0 to 25.0552
 Factory-InstalledField-Installed
Cabinet
Thru the base electrical or gas line connectionsXX
Hinged access panelsX 
Coil Options

Cu/Cu indoor and/or outdoor coils

X 
Pre-coated outdoor coilsX 
Premium, e-coated outdoor coilsX 
Humidity Control
Humidi-MiZer adaptive dehumidification system (3-phase models only)X 
Condenser Protection
Condenser coil hail guard (louvered design)XX
Controls
Thermostats, temperature sensors and subbases X
PremierLink DDC communicating controllerXX
RTU Open multi-protocol controllerXX
Smoke detector (supply and/or return air)X 
Time Guard II compressor delay control circuit X
Filter status switch X
Fan status switch X
Economizers & Outdoor Air Dampers

EconoMi$er IV (for electro-mechanical controlled RTUs) 

XX

EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)

XX
EconoMi$er 2 (for DDC controlled RTUs)XX
Ultra-low leak economizer dampersXX
Motorized 2-position outdoor air damperXX
Manual outdoor dir damper X
Barometric reliefXX
Power exhaust X
Economizer Sensors & IAQ Devices
Single dry bulb temperature sensorsXX
Differential dry bulb temperature sensors X
Single enthalpy sensorsXX
Differential enthalpy sensors X
CO2 sensor (wall, duct, or unit mounted)XX
Electric Heat
Multiple electric resistance heater kW sizes X
Single point kit X
Indoor Motor & Drive
Multiple motor and drive packagesX 
Low Ambient Control
Winter start kit X
Motormaster head pressure controller X
Power Options
Convenience outlet (powered)X 
Convenience outlet (unpowered)X 
Non-fused disconnectX 
Roof Curbs
Roof curb 14" (356mm) X
Roof curb 24" (610mm) X