ADP C-Series Cased A-Coil Upflow/Downflow

  • California Prop 65
Grouped product items
Product Name
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide P16 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L169
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L18 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L189
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide P18 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L189
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L159
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide L19 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L199
ADP Nominal 3 Ton, Upflow/Downflow 17.5" Wide L53 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A175L539N
ADP Nominal 3 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A175L159N
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L18 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L189N
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L159N
ADP Nominal 3 Ton, Upflow/Downflow 17.5" Wide L13 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A175L139N
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide P18 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L189N
ADP Nominal 5 Ton, Upflow/Downflow 24.5" Wide L25 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A245L259N
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide L19 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L199N
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L16 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L169N
ADP Nominal 3 Ton, Upflow/Downflow 14.25" Wide L13 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A142L139N
ADP Nominal 4 Ton, Upflow/Downflow 21" Wide L15 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A210L159N
ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L53 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C48A175L539N
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide P16 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L169N
ADP Nominal 5 Ton, Upflow/Downflow 21" Wide L52 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C60A210L529N
ADP Nominal 3 Ton, Upflow/Downflow 14.25" Wide L53 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A142L539N
ADP Nominal 3 Ton, Upflow/Downflow 14.25" Wide L13 A-Coil, Aluminum, Non-Bleed TXV
MFR:
Item:
C36A142L139
6" Downflow Spacer for ADP CxxA Coil (14-1/2" Width)
MFR:
Item:
DFSK-142
6" Downflow Spacer for ADP CxxA Coil (17-1/2" Width)
MFR:
Item:
DFSK-175
6" Downflow Spacer for ADP CxxA Coil (21-1/2" Width)
MFR:
Item:
DFSK-210
6" Downflow Spacer for ADP CxxA Coil (24-1/2" Width)
MFR:
Item:
DFSK-245

Product Features:
• High efficiency lanced fin design.
• “No-hassle” 5 year warranty, with an additional 5 years upon registration at www.adpwarranty.com
• R-410A TXVs installed. Threaded installation.
• All coils have durable packaging with bar coded labels on the box.
• Coils are air pressure tested at 500 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air.
• Liquid line refrigerant connections are 3/8" ODF.
• Suction line refrigerant connections are 3/4" ODF (A-Coil 18-36 size models) or 7/8" ODF (A-Coil 42-60 size models).
• Copper refrigerant connections for easy brazing on both copper and aluminum slab models.
• Cased coils have heavy gauge painted cabinets fully lined with 5/8" foil faced insulation.
• Corrosion resistant coil header plates.
• All A-Coils are upflow or downflow capable.
• Cabinet insulation hold down tabs for easy drain pan removal. Bottom Opening Width is cabinet width less 1"
• Interlocking doors reduce air leakage and allow for easy access. Bottom opening Depth is cabinet depth less .5"
• Enhanced refrigerant pipe grommets: secure, tight, and easy to install. Top Opening Width is cabinet Width less 1.5"
• Intertek lab tested 1% or less cabinet air leakage for better efficiency. Top opening Depth is cabinet depth less 1.5"
• Foam drain seal for reduced air leakage. Cabinet Height doesn't include 3/4" duct flange.
• Non-captive refrigerant lines with long stubs make for easy installation.
• Dual 3/4" FPT condensate drains on front-left and front-right side of drain pans.
• UV resistant drain pans are molded of high temperature (450 deg. F) engineered polymer.
• Microban® antimicrobial additive to inhibit the growth of mold and mildew in the drain pan.
• HydroTEC™ low water retention drain pan.