Bryant Legacy 10 Ton, 11 EER, Package RTU Gas Heat/Elec Cool, Two Stage Cooling 208/3
Item
580JP12N180A2A0AA
580J Legacy Single-Packaged Standard Efficiency Gas Heating/Electric Cooling Rooftop Unit with Puron® Refrigerant
Durable Economic Comfort for Commercial Building Applications
The 580J rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with environmentally sound Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.
FEATURES AND BENEFITS
• Single circuit, single stage cooling model on 6 ton
• Single circuit, 2-stage cooling models are available from 7.5 to 10 ton.
• Dual circuit 2-stage cooling stage models are available from 7.5 to 15 ton.
• EERs up to 11.1 with IEERs up to 12.8
• 2-speed indoor fan motor system automatically adjusts the indoor fan motor speed between cooling stages. Standard on all
580J*08-16D/F/K/M units for installation in the United States to meet the Department of Energy (DOE) efficiency standard of
2018. Factory option for all 580J*08-16D/F/K/M unit installations outside the United States. 580J*08/09/12/N or P units meet the
DOE 2018 efficiency standard without the 2-speed indoor fan motor option.
• Utility connections are the same because 6 to 12.5 ton units fit on existing Bryant rooftop curbs. This saves time and money on
replacement jobs.
• Standardized components and layout. Standardized components and controls make service and stocking parts easier.
• Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
• Field convertible airflow (6 to 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome
job site complications. A 15 ton model requires a simple supply duct cover to field convert from factory vertical to horizontal.
• Easy-adjust, belt-drive motor available.
• Provisions for bottom or side condensate drain.
• Capable of thru-the-base or thru-the-curb gas line routing.
• Single-point gas / electrical connection.
• Internally sloped, composite drain pan sheds water; and won’t rust.
• Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier.
• Tool-less filter access door.
• Clean, large, easy to use control box.
• Color-coded wiring.
• Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
• Single, central terminal board for test and wiring connections.
• Fast-access, handled, panels for easy access on normally accessed service panels.
• “No-strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit.
• Mechanical cooling (115°F to 40°F or 46°C to 4°C) standard on all models. Winter Start Kit allows cooling operation down to
25°F (–4°C) and Motormaster® option to –20°F (–29°C).
• High efficiency, gas heat with induced-draft flue exhaust design.
• Induced draft motor ensures no flue gas can escape into the indoor air stream.
• Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense.
• 2-in. (51 mm) disposable filters on all units.
• Refrigerant filter-drier on each circuit.
• Each circuit is protected with a high and low pressure switch.
• Many factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switches and smoke detectors.
• Standard (limited parts only) Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation® condenser coil, 1 yr.
parts.
• Factory-installed Perfect Humidity™ dehumidification system on all sizes with round tube / plate fin condenser coils, includes
Motormaster I controller.
• Single circuit, 2-stage cooling models are available from 7.5 to 10 ton.
• Dual circuit 2-stage cooling stage models are available from 7.5 to 15 ton.
• EERs up to 11.1 with IEERs up to 12.8
• 2-speed indoor fan motor system automatically adjusts the indoor fan motor speed between cooling stages. Standard on all
580J*08-16D/F/K/M units for installation in the United States to meet the Department of Energy (DOE) efficiency standard of
2018. Factory option for all 580J*08-16D/F/K/M unit installations outside the United States. 580J*08/09/12/N or P units meet the
DOE 2018 efficiency standard without the 2-speed indoor fan motor option.
• Utility connections are the same because 6 to 12.5 ton units fit on existing Bryant rooftop curbs. This saves time and money on
replacement jobs.
• Standardized components and layout. Standardized components and controls make service and stocking parts easier.
• Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
• Field convertible airflow (6 to 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome
job site complications. A 15 ton model requires a simple supply duct cover to field convert from factory vertical to horizontal.
• Easy-adjust, belt-drive motor available.
• Provisions for bottom or side condensate drain.
• Capable of thru-the-base or thru-the-curb gas line routing.
• Single-point gas / electrical connection.
• Internally sloped, composite drain pan sheds water; and won’t rust.
• Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier.
• Tool-less filter access door.
• Clean, large, easy to use control box.
• Color-coded wiring.
• Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
• Single, central terminal board for test and wiring connections.
• Fast-access, handled, panels for easy access on normally accessed service panels.
• “No-strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit.
• Mechanical cooling (115°F to 40°F or 46°C to 4°C) standard on all models. Winter Start Kit allows cooling operation down to
25°F (–4°C) and Motormaster® option to –20°F (–29°C).
• High efficiency, gas heat with induced-draft flue exhaust design.
• Induced draft motor ensures no flue gas can escape into the indoor air stream.
• Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense.
• 2-in. (51 mm) disposable filters on all units.
• Refrigerant filter-drier on each circuit.
• Each circuit is protected with a high and low pressure switch.
• Many factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switches and smoke detectors.
• Standard (limited parts only) Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation® condenser coil, 1 yr.
parts.
• Factory-installed Perfect Humidity™ dehumidification system on all sizes with round tube / plate fin condenser coils, includes
Motormaster I controller.
Electrical | |
---|---|
FLA | 1.5 | Hertz | 60 | LRA | 314 | MCA | 55 | MOCP | 80 | Phase | 3 | RLA | 15.6 | Voltage | 208/230 |
Specification | |
---|---|
Heat Exchanger Type | Aluminum | High Pressure Switch | Yes | IEER | 11.8 | Ignition Type | Direct-Spark | Low Pressure Switch | Yes | Metering Device | Acutrol | Gas Type | Natural Gas | Net Cooling Capacity | 114000 | Net Heating Capacity | 148000 | Refrigerant | R-410A | Rows | 2 | Rows/FPI | 17 | Sound Level | 82 | Tonnage | 10 | Condenser Motor HP | 0.25 | Blower Motor Type | Belt Drive | Blower Speeds | 1 | Blower Wheel | 15 X 15 | BTU Output | 120000 | CFM | 4,000 | Compressor Type | Scroll | Condensate Connection Size | 0.75 | Blower Motor HP | 3.7 | Condenser Motor Type | Direct Drive | Condenser RPM | 1100 | Cooling Stages | 2 | EER | 11 | Filter Size | (4) 20x20x2 | Gas Connection Size | 1/2" NPT | Gas Heating | 180000 |
Safety Standards | |
---|---|
California Prop 65 | Yes | ETL Certified | Yes |
Weights and Dimensions | |
---|---|
Operating Weight (lbs) | 940 | Exterior Dimensions (D) (inches) | 88.130000 | Exterior Dimensions (W) (inches) | 59.500000 | Exterior Dimensions (H) (inches) | 49.380000 | Shipping Weight (lbs) | 990.000000 |
Warranty | |
---|---|
Compressor Warranty | 5 Year | Parts Warranty | 1 Year |
General | |
---|---|
Tier | Legacy |