Bryant Legacy Multipoise Furnace, 80% AFUE, 100,000 BTU, Communicating Ultra-Low NOx,(SCAQMD/SJVAPCD Compliant), 115/1

Item
830CA60100C21
  • California Prop 65

EVOLUTION® 80 ULTRA LOW NOx GAS FURNACE

The 830CA delivers home comfort in an 80% AFUE furnace that meets the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for South Coast Air Quality Management District and San Joaquin Valley Air Pollution Control District in California. It provides warm winter heating with 65% lower NOx emissions than standard models. The Evolution® 80 Ultra Low NOx Gas Furnaces offers a number of comfort-enhancing features with its variable-speed, fully communicating blower motor. FanOnPlus™ technology selectable fan speeds allows control over ventilation. SmartEvap™ technology provides humidity control during cooling operation, and with select outdoor units, Perfect Humidity™ technology provides significantly better dehumidification. And, when paired with a two-speed or variable-speed outdoor unit, homeowners will enjoy consistent summer comfort.

STANDARD FEATURES

Efficiency

• 80% AFUE.
• 40K, 60K, 80K, 100K Btu/h capacities.
• Ultra-low NOx emissions - 830CA meets the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for the South Coast Air Quality Management District and San Joaquin Valley Air Pollution Control District in California.

Technology

• Single-stage gas valve.
• Variable speed constant airflow ECM blower motor.
• Pre-mix burner with pilot free, hot surface ignition.
• Variable speed inducer motor.
• Stainless steel, tubular heat exchanger.

Performance

• Integral part of the PerfectHumidity System:
       - Maximum dehumidification selection for summer time cooling.
       - Full PerfectHumidity benefits including “Super Dehumidify” SmartEvap™ Humidity control when using a Thermidistat™ / Evolution™ control.
• SmartEvap™ can lower the humidity level in the home by nearly 10 percent.
• Perfect Light™ Ignitor.
• Microprocessor based control center:
      - Enhanced diagnostics with LED and reflective sight glass Stores fault codes during power outages.
      - Adjustable heating air temperature rise.
      - Adjustable heating and cooling airflow.
      - Dehumidification selection for summer-time cooling.
• Draft Safeguard switch designed to ensure proper furnace venting.
• Insulated blower compartment.
• Inner door for tighter sealing.
• HYBRID HEAT® Dual Fuel System compatible.

Design and Installation

• Approved for installation up to 5,400 feet.
• Versatile venting for tight-fit applications.
• Factory shipped for natural gas, not convertible to propane.
• Four-position furnace: Upflow, Horizontal Right, Horizontal Left, Downflow. (with 6 different vent options)
• Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193.

Specification
Fuel Type Natural Gas Only
Stages Single Stage
Number of Burners 5
Maximum Pressure 13.6
Ignition Type Silicon Nitride Hot Surface
Heat Exchanger Type Stainless Steel Tubular
Gas Connection Size 1/2 - NPT
AFUE 80
CFM Heating 1750
CFM Cooling 2260
BTU Output 80000
BTU Input 100000
Blower Wheel 11 X 11
Blower Speeds Communicating Variable Speed
Blower Motor Type Variable-Speed, Constant Airflow ECM
Blower Motor RPM 1050
Blower Motor HP 1
Electrical
Hertz 60
MOCP 20
Phase 1
Voltage 115
Safety Standards
California Prop 65 Yes
Energy Star Rated No
ETL Certified No
ETL Listed No
Hazardous Material No
Leed Certified No
Shipping Point 46231
UL Listed No
Weights and Dimensions
Operating Weight (lbs) 154
Exterior Dimensions (D) (inches) 29.000000
Exterior Dimensions (W) (inches) 21.000000
Exterior Dimensions (H) (inches) 33.250000
Shipping Weight (lbs) 154.000000
General
Tier Evolution