Bryant Legacy™ Multipoise Furnace, 90% AFUE, Single-Stage, 18 Speed ECM, Ultra Low Nox (SCAQMD/SJVAPCD Compliant), 115/1
Overview
The 935SB Legacy™ Line 95 Ultra-Low NOx gas furnace delivers consumer comfort in a unit that meets California’s South Coast Air Quality Management District (SCAQMD) and San Joaquin Valley Air
pollution Control District (SJVAPCD) NOx emissions limit of 14ng/J. Offering the performance and benefits of our Legacy Line gas furnaces, this furnace releases 65% less nitrogen oxides (NOx) than previous
models. NOx contributes to the formation of smog and acid rain and the deterioration of water quality. Lower NOx emissions mean lower production of particulate matter and cleaner air for the environment.
Energy efficiency is at the heart of this furnace with up to 95.0% AFUE gas efficiency and the electrically-efficient fixed-speeds, constant torque (MCT) ECM blower motor. Improved serviceability with the 3 digit
status display and NFC enabled board allowing setup via the service tech app. This gas furnace also features Upflow/Horizontal installation flexibility, and is available in four model sizes. All sizes can be vented
for direct vent/two-pipe, ventilated combustion air, or single-pipe applications.
PERFORMANCE
• Ultra Low NOx - meets the nitrogen oxides (NOx) emission limit of 14 nanograms/joule for the South Coast Air Quality Management Districts and San Joaquin Valley Air Pollution Control District in California
• Multi 18-speed, constant torque (MCT) ECM blower motor for electrically efficient operation all year long in heating, cooling and mcontinuous fan operation
• Single-stage gas valve with pre-mix burner
• Two-stage cooling capability
• Pilot free, hot surface ignition
• Variable-speed inducer motor for consistent operation
• High temperature limit control designed to prevent overheating
• Adjustable blower speed for heating and cooling
• Enhanced diagnostics with easy to read 3 digit display for faults and status
• Stainless-steel primary heat exchanger
• Stainless-steel condensing secondary heat exchanger
• Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE Standard 193
INSTALLATION FLEXIBILITY
• Upflow/Horizontal design for upflow, horizontal right or horizontal left installation, with rotating vent elbow for exhaust venting flexibility
• On-board NFC antenna makes setup a tap away when using the Bryant service technician app
• Factory-configured ready for upflow applications.
• Features a 6-3/8” condensate trap (7-3/8” service clearance recommended in horizontal applications).
• Two-pipe venting, single-pipe venting or ventilated combustion air.
APPLICATIONS
• Factory-configured for Natural Gas; not convertible to Liquid Propane.
• Not approved for downflow installation
• Approved for installations up to 5,400 ft.