Carrier 15 Ton, 10.6 EER, Heat Pump Condenser, 460/3

Item
38AUQA16A0A60A0A0
  • California Prop 65

Commercial Split System Heat Pump
with Puron® Refrigerant

6 to 20 Nominal Tons

The Gemini® 38AU series outdoor units and matched with the 40RU series indoor air handlers offer a wide variety of options for your HVAC application needs. This series is designed for long dependable operation whether it's a rooftop or on-the-ground installation. All GEMINI 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.

Performance Features

  • 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP
  • ASHRAE 90.1 Efficiency Compliant
  • Standard crankcase heater
  • Compressor vibration isolation
  • Low ambient temperature control
  • Unit performance certified in accordance with ARI standard 340/360

Reliability Features

  • High and low-pressure switches
  • Anti-short cycling protection
  • Prepainted, galvanized steel cabinets that passes 500-hour salt-spray test
  • Compressor overload protection
  • Scroll compressor
  • E-Coat coil protection
  • UL, UL, Canada or ETL approved

Installation Features

  • Shipped with Puron (R-410A) refrigerant partial charge
  • Single-piece design
  • Perimeter base rail with forklift slots and lifting holes facilitates rigging
  • Suitable for mounting on the ground or the rooftop
  • 24V control circuit transformer permits quick, easy wiring of thermostats

Maintenance Features

  • Comfort Alert™ diagnostic board
  • Powered and non-powered 115-v convenience outlet
  • Compressor access panel with easy grip handle
  • Easy starting, no-strip screw feature
  • Non-fused disconnect switch

Standard Limited Warranty

  • 5 years parts only on compressor
  • One year parts only on all other parts

38AUQ/40RUQ AHRI Cooling Ratings

UnitCooling StagesNominal Capacity (Tons)Net Cooling Capacity (MBH)Total Power (kW)EERIEER
38AUQ07 / 40RUQ071670.06.411.012.6
38AUQ08 / 40RUQ0817.589.08.111.012.0
38AUQ12 / 40RUQ12110112.010.211.012.0
38AUQ16 / 40RUQ16215178.016.810.611.0
38AUQ25 / 40RUQ25220220.020.810.711.0

38AUQ/40RUQ AHRI High Heat Ratings at 47°F (8°C)

UnitHeating StagesNominal Capacity (Tons)Net Cooling Capacity (MBH)Total Power (kW)COP
38AUQ07 / 40RUQ071666.05.93.30
38AUQ08 / 40RUQ0817.587.07.73.30
38AUQ12 / 40RUQ12110106.09.43.30
38AUQ16 / 40RUQ16215178.015.33.40
38AUQ25 / 40RUQ25220214.017.93.50

38AUQ/40RUQ AHRI Low Heat Ratings at 17°F (-8°C)

UnitHeating StagesNominal Capacity (Tons)Net Cooling Capacity (MBH)Total Power (kW)COP
38AUQ07 / 40RUQ071639.05.22.20
38AUQ08 / 40RUQ0817.552.06.92.20
38AUQ12 / 40RUQ1211070.09.32.20
38AUQ16 / 40RUQ16215108.013.22.40
38AUQ25 / 40RUQ25220130.015.92.40

LEGEND
AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance

NOTES
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.

Factory-Installed Options

  • Non-fused Disconnect
  • Premium, E-coated condenser coil
  • Convenience outlet (powered)
  • Low ambient temperature Motormaster® control
  • Louvered hail guards

Field-Installed Accessories

  • Low ambient temperature Motormaster® control
  • Louvered hail guard
  • Programmable thermostats
Electrical
FLA 0.8
Hertz 60
LRA 100
MCA 23.9
MOCP 30
Phase 3
RLA 12.2
Voltage 460
Safety Standards
California Prop 65 Yes
Specification
Low Pressure Switch Yes
Tonnage 15
Suction Line Size 1 3/8
Sound Level 80
Rows/FPI 2
Rows 2
Refrigerant R-410A
Min Ambient Temperature 35
Liquid Line Size 1/2
High Pressure Switch Yes
COP 3.4
Cooling Stages 1
Condenser RPM 1100
Condenser Motor Type Direct Drive
Condenser Motor HP 1/4
Condenser Air Flow Vertical
Compressor Type Scroll
Weights and Dimensions
Operating Weight (lbs) 883
Exterior Dimensions (D) (inches) 86.380000
Exterior Dimensions (W) (inches) 45.130000
Exterior Dimensions (H) (inches) 50.380000
Shipping Weight (lbs) 768.000000