Rooftop Unit Open Controller (Requires Harness)

Item
OPN-RTUM2
  • California Prop 65

OVERVIEW

Product Integrated Controller

Integrated controller for rooftop units capable of stand-alone operation or integrated with Carrier’s or any Building Automation System using BACnet®, Modbus® or Lonworks® protocol.

The RTU Open controller continuously monitors and regulates constant volume rooftop operation with reliability and precision. This advanced controller features a sophisticated, factory-engineered control program that provides optimum performance and energy efficiency. It also features plug-and-play connectivity to the Carrier i-Vu Building Automation System.

For added flexibility, the RTU Open controller is capable of stand-alone operation, or, it can be integrated with any other Building Automation System utilizing the BACnet, Modbus®, LonWorks®, or N2 protocols.


FEATURES

System Benefits
Integrated Carrier airside linkage algorithm for plug and-play integration with the Carrier VVT® System
Fully plug-and-play with the Carrier i-Vu Building Automation System
Supports demand limiting for maximum energy savings
Compatible with i-Vu Tenant Billing for tracking tenants’ after-hours energy usage
Performance and utilization runtime data stored locally on the controller for system

Hardware Features
Can be factory-installed on Carrier WeatherExpert®, WeatherMaster®, and WeatherMaker® packaged rooftop units
Can be field-installed on constant volume rooftop units; wiring harnesses (sold separately), provide quick field installation
Integrates easily into any BAS using BACnet, Modbus, LonWorks1, or N2 protocols
On-board hardware clock, remote occupancy input, and support for Carrier communicating room sensors/thermistor sensors provide stand-alone operation
Easy startup and configuration with i-Vu User Interfaces

Application Features
Controls up to 2 stages of DX cooling (3 stages for 48/50 LC WeatherExpert®) to maintain space temperature setpoint
Controls up to 2 stages of gas heat or combination of mechanical and electric heat to maintain space temperature setpoint (controls up to 4 stages of heat in heat pump mode)
Integrated economizer2 and power exhaust control provide optimized free cooling in combination with mechanical cooling
2 fan speed control options provide maximum energy savings and comfort
Built-in advanced control routines for zone level humidity control or zone level demand control ventilation (ASHRAE 62)
Safety Standards
California Prop 65 Yes
Hazardous Material No
Weights and Dimensions
Operating Weight (lbs) 1
Exterior Dimensions (D) (inches) 7.000000
Exterior Dimensions (W) (inches) 7.000000
Exterior Dimensions (H) (inches) 2.000000
Shipping Weight (lbs) 1.500000