RenewAire® SL Energy Recovery Ventilator 6-8" Round Ducts, 130CFM, 120Vac

Item
SL75
  • California Prop 65

FEATURES

In response to growing demand for smaller and more flexible units, RenewAire offers the slimline SL Series ERVs. The ETL Listed and HVI-Certified SL Series is compact, fits into tight spaces and incorporates high-efficiency EC-motor fans to meet strict California energy codes.

These ERVs have Dial-A-Flow controllers that allows users to set airflow for maximizing comfort. In addition, they also have boost-mode capabilities for on demand greater airflows and with MERV 13 filters as an accessory to further enhance IAQ. These ERVs are perfect for high-rise condos, apartments, townhouses, residential homes, compartmentalized commercial spaces with minimal bulkhead and ceiling space, and Passive House.


CERTIFICATION
  • • Commercial Units
    • ○ Certified by the Air Conditioning, Heating and Refrigeration Institute (AHRI) for an industry-leading, low-to-zero Exhaust Air Transfer Ratio (EATR) at typical static pressure differential.
  • • Residential Units
    • ○ Certified by the Home Ventilating Institute (HVI) against standard CAN/CSA-C439-18 for an industry leading CFM/watt and energy transfer effectiveness (except BR 70).
  • • Superior core flammability performance; passes UL-723 and UL-1812.

  • MAINTENANCE
  • • RenewAire cores are easy to clean without removing them from the unit, and they never require washing.

  • INNOVATIVE CONSTRUCTION
  • • Core exchanger material is cellulosic-based and doesn’t contain or use halogenated flame retardants or PVCs.
  • • Manufactured with a galvanized steel frame.

  • RELIABILITY
  • • An industry-leading 10-year structural and performance warranty for the static-plate core, two-year warranty for commercial products and five-year warranty for residential products.

  • EXCEPTIONAL PERFORMANCE
  • • Moderates heat and humidity via total energy recovery to maintain a comfortable indoor environment.
  • • No need for frost protection or condensate pans.
  • • Laminar airflow ensures that particulates do not accumulate in the core.

  • REDUCED COSTS
  • • Optimized energy efficiency via core energy transfer decreases ventilation energy requirements, which can result in smaller air conditioning and heating needs.

  • SPECIFICATIONS

  • • Ventilation Type: Static plate, heat and humidity transfer
  • • Typical Airflow Range: 30–130 CFM
  • • Unit is HVI Tested/Certified per CSA C439 Protocol: Using one L-30-G5 Core
  • • White painted cabinet
  • • Line-cord power supply or hard wired to junction box (H)
  • • Low-voltage circuit for controls
  • • Unit may be mounted in any orientation
  • • Cross-core differential pressure ports
  • • Dial-A-Flow: balance and airflow adjustment
  • • Variable speed
  • • Boost-mode
  • • Controls: Onboard digital controller with independent variable speeds
  • • Filters: Total qty. 2, MERV 8, spun-polyester media: 7 1/2" x 10 1/2" x 1"
  • • Unit Weight: 35 lbs.
  • • Motor(s): Qty. 2, 120V EC motorized impellers
  • • Wattage: 53
  • • Voltage: 120Vac
  • • Hz: 60
  • • Phase: 1
  • • FLA per motor: 0.85
  • • Minimum Circuit Amps: 15
  • • Max Overcurrent Protection Device: 15
  • Safety Standards
    California Prop 65 Yes
    Weights and Dimensions
    Operating Weight (lbs) 41
    Exterior Dimensions (D) (inches) 32.000000
    Exterior Dimensions (W) (inches) 23.000000
    Exterior Dimensions (H) (inches) 15.000000
    Shipping Weight (lbs) 41.000000
    Specification
    CFM 130