WeatherMaker® 3 to 10 Nominal Tons Packaged Rooftop Cooling Only with EcoBlue™ Technology

  • California Prop 65
Grouped product items
Product Name
Carrier Nominal 3 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/1
MFR:
Item:
50FCA04A2A30A0A0
Carrier Nominal 3 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/3
MFR:
Item:
50FCA04A2A50A0A0
Carrier Nominal 3 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 460/3
MFR:
Item:
50FCA04A2A60A0A0
Carrier Nominal 4 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/1
MFR:
Item:
50FCA05A2A30A0A0
Carrier Nominal 4 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/3
MFR:
Item:
50FCA05A2A50A0A0
Carrier Nominal 4 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 460/3
MFR:
Item:
50FCA05A2A60A0A0
Carrier Nominal 5 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/1
MFR:
Item:
50FCA06A2A30A0A0
Carrier Nominal 5 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 208/3
MFR:
Item:
50FCA06A2A50A0A0
Carrier Nominal 5 Ton, 14.0 SEER, Package RTU Cooling Only, Single Stage, 460/3
MFR:
Item:
50FCA06A2A60A0A0
Carrier Nominal 6 Ton, 11.2 EER, Package RTU Cooling Only, Two Stage, 208/3
MFR:
Item:
50FCM07A2A50A0A0
Carrier Nominal 6 Ton, 11.2 EER, Package RTU Cooling Only, Two Stage, 460/3
MFR:
Item:
50FCM07A2A60A0A0
Carrier Nominal 7.5 Ton, 11.4 EER, Package RTU Cooling Only, Two Stage, 208/3
MFR:
Item:
50FCM08A2A50A0A0
Carrier Nominal 7.5 Ton, 11.4 EER, Package RTU Cooling Only, Two Stage, 460/3
MFR:
Item:
50FCM08A2A60A0A0
Carrier Nominal 8.5 Ton, 11.4 EER, Package RTU Cooling Only, Two Stage, 208/3
MFR:
Item:
50FCM09A2A50A0A0
Carrier Nominal 8.5 Ton, 11.4 EER, Package RTU Cooling Only, Two Stage, 460/3
MFR:
Item:
50FCM09A2A60A0A0
Carrier Nominal 10 Ton, 11.2 EER, Package RTU Cooling Only, Two Stage, 208/3
MFR:
Item:
50FCM12A2A50A0A0
Carrier Nominal 10 Ton, 11.2 EER, Package RTU Cooling Only, Two Stage, 460/3
MFR:
Item:
50FCM12A2A60A0A0

OVERVIEW

Electric Heat / Electric Cooling & Cooling Only with Ecoblue™ Technology

3 to 6 Nominal Tons

Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The industry’s first beltless direct-drive vane axial fan for rooftop units* is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors and more – all available on this multiefficiency offering.

*Available on select models

FEATURES

Performance Features

  • Meets and exceeds ASHRAE 90.1 energy efficiency levels
  • New unit control board with intuitive quick fan speed adjustment
  • New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor
  • Single-stage cooling capacity 04-06 models, two-stage on 07 models
  • SEERs up to 14.0, IEER of 15.2
  • Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit
  • Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection

Maintenance Features

  • New unit control board facilitating simple safety circuit troubleshooting and simplified control box arrangement as well as easy intuitive fan speed adjustment
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Tool-less filter access door
  • Optional hinged access panels also available
  • NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design
  • Two-inch disposable return air filters

Installation Features

  • Same footprint as prior Carrier models for that original fit; reduces installation costs and time
  • Field convertible from vertical to horizontal airflow configuration
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point electric, and controls connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots

Reliability Features

  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated direct-drive ECM evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection

Standard Limited Warranty

  • 5 years electric heaters
  • 5 years parts only compressor
  • 3 year SystemVu™ controller
  • One year parts only on all other parts
  • Additional extended warranty packages available

California residents please see Proposition 65


OPTIONS

Factory-Installed Options

  • Temperature Sensing EconoMi$er with relief
  • Enthalpy Sensing EconoMi$er with relief
  • Humidi-MiZer® Adaptive Dehumidification System
  • Return Air Smoke Detector
  • Supply Air Smoke Detector
  • CO2 Sensor
  • Condensate Overflow Protection
  • Multiple Static Fan Capabilities
  • Phase Monitor/Protection
  • Thru-The-Base Utility Connections
  • Louvered Hail Guards
  • Non-Fused Disconnect Switch
  • MERV-8 Return Air Filters
  • Hinged Access Panels
  • Unpowered Convenience Outlet
  • Powered Convenience Outlet
  • Coated Coils:
    • Pre-Coat
    • E-Coat
    • Copper/Copper
  • Electrical Mechanical Controls
  • SystemVu™ Integrated Communicating Controls
  • RTU-Open Communicating Controls
  • Extended Warranty Protection Plans
  • Financing Available